G5.Api
1.22.0.121
.Net API to control Regatron G5 devices
Loading...
Searching...
No Matches
Class List
Here are the classes, structs, unions and interfaces with brief descriptions:
[detail level
1
2
3
4
5
]
▼
N
Regatron
▼
N
G5
▼
N
Api
▼
N
Boards
C
Board
C
BoardInformation
C
BoardState
C
ControllerBoard
C
ControllerBoardInformation
C
ConverterBoard
C
ConverterBoardInformation
▼
N
Devices
C
Device
C
DeviceBase< TControllerBoard, TConverterBoard >
C
DeviceInformation
C
DeviceReversePolarityProtection
C
DeviceState
▼
N
System
C
ActiveInterface
C
ActualSystemValues
C
BaseSweepConfiguration
C
BaseSweepParameters
C
BatteryControl
This class contains the specific methods for battery simulation.
C
CurrentLoadProtection
C
DataExchange
DataExchange
provides methods to read and write values from/to
dedicated objects out of the ObjectDirectory of the
G5
device.
The object addressing consists of a device id,
board id, object-group index and object index
C
EthernetConfiguration
C
FrequencySweepConfiguration
C
FrequencySweepParameters
C
FunctionGenerator
C
FunctionGeneratorBlockConfiguration
C
FunctionGeneratorPreview
C
FunctionGeneratorSequenceConfiguration
C
FunctionGeneratorSequenceManagement
C
G5System
G5System
is the root object of this library.
It is the entry point to all the functionality of this library.
You can create multiple number of instances by using:
Regatron.G5.Api.System.G5System.CreateSystem
C
G5SystemBase< TDevice, TControllerBoard, TConverterBoard >
C
I2TObservation
C
LicenseInformation
C
LoadProtection
C
OutputControl
C
OutputMeasurement
C
ParameterSetConfiguration
This class provides methods for accessing
or modifying parameter set information
C
PeakSweepConfiguration
C
PeakSweepParameters
C
PeriodsStepFrequencySweepConfiguration
C
PowerLoadProtection
C
ReferenceValues
C
ReferenceValueSource
C
Safety
C
Sensing
C
SolarArraySimulation
This class contains the specific methods to configure a solar array simulation.
Other needed methods for automated testing can be found in:
Regatron.G5.Api.System.FunctionGenerator
Regatron.G5.Api.System.FunctionGeneratorBlockConfiguration
Regatron.G5.Api.System.FunctionGeneratorSequenceConfiguration
Regatron.G5.Api.System.FunctionGeneratorSequenceManagement
After configuring a solar array simulation you need to start the simulation with
Regatron.G5.Api.System.FunctionGenerator.SetCommand
C
SolarArraySimulationCellTechnologyParameters
Container class for the solar array simulation solar cell technology parameters
C
SteadyFrequencySweepConfiguration
C
SteadyPeakSweepConfiguration
C
SteadySweepConfiguration
C
StepSweepConfiguration
C
SystemCharacteristics
C
SystemCommands
C
SystemInformation
C
SystemReversePolarityProtection
C
SystemState
C
TimeStepFrequencySweepConfiguration
C
TimeStepPeakSweepConfiguration
C
VoltageLoadProtection
C
ApiInformation
C
Commands
C
G5ApiException
C
Incident
C
ParameterSetInformation
C
Point
▼
N
Common
C
ActiveInterfaceInformationDetails
C
ISequenceInformation
C
Exception
Generated on Thu Aug 28 2025 11:48:30 for G5.Api by
1.13.2